• Overview
  • Features
  • Specifications
  • Accessories

Optimized Return on Investment

With storage virtualization technology, the capacity and computing power of multiple ESVA systems can be consolidated into a storage pool. For the most efficient utilization of pooled storage capacity and bandwidth, ESVA systems support thin-provisioning and an intelligent access prioritizing mechanism on the virtual architecture. With these advanced features, storage utilization can be optimized and applications can achieve their ideal service levels. ESVA delivers advanced technologies to make the most of your storage investment.

Simplified Storage Infrastructure

ESVA simplifies storage management by enabling a single point of administration. Scaling the storage pool is also a very easy task and can be done without disrupting service. Each ESVA system can be scaled for increased capacity by connecting it to expansion enclosures. If you want to increase capacity and performance at the same time, you can also scale out the virtualized foundation by adding additional ESVA systems. When a new system is added, the distributed load balancing technology will dynamically balance workloads among storage systems and increase processing power.

Maximized Application Productivity 

In the competitive business world, downtime not only causes profit loss but can inflict damage on corporate reputations. The revolutionary architecture of the ESVA eliminates planned downtime for storage scaling. To support business continuity, it also comes with storage-based replication capabilities. Local replication offers snapshot images and full data copies in a single storage pool, while remote replication enables users to deploy full data copies across storage pools. The hybrid model F70 features four iSCSI channels that help users achieve highly cost-effective remote replication. You enjoy the highest data availability and minimized service downtime in the event of logical or physical errors.

Advanced Hardware Designs

All ESVA systems are based on High Availability (HA) modular design to achieve high fault-tolerant capability. For better cached data protection, the ESVA systems come with built-in CacheSafe technology. In the event of a power outage, the BBU will automatically supply power to write cached data into flash memory for permanent retention. Infortrend enriches the ESVA Series with energy efficient designs, contributing to environmental sustainability while cutting energy costs for companies.

Features Benefits
Storage virtualization Eliminate physical boundaries of storage consolidation
Thin provisioning Ensure the most efficient allocation of pooled capacity
Distributed load balancing Make performance grow linearly by adding subsystems to the virtualized foundation
Prioritized volume accessibility Ensure applications to achieve their ideal service levels

Data protection:

  1. Snapshot
  2. Volume copy/Volume Mirror
  3. Sync and async remote replication
Support the highest data availability and quick service restart after storage accidents
Eight 8Gb/s Fibre Channel host ports
  1. Best-of-class throughput and IOPS, ideal fit for IO-intensive and bandwidth-demanding applications
  2. Backward compatible with 4G or 2G speeds, protecting current infrastructure investment
Four 1Gb/s iSCSI ports Achieve highly cost-effective remote replication through iSCSI ports

Green design:

  1. High-efficiency power supplies
  2. Intelligent multi-level drive spin-down technology
  1. Power supplies delivering more than 80% of energy conversion efficiency
  2. In spin-down state, drives can save up to 60% of energy consumption
CacheSafe technology Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage
Fault-tolerant hardware modules Redundant controllers, PSUs, fans; high-availability hardware design, preventing "single-point-of-failure"
Maximum expansion of six JBODs via multi-lane SAS links, up to 112 HDDs in total "Pay-as-you-grow" scalability; no waste on what you don’t need, and no worries in terms of forecasting what you will need in the future
Powerful management suite (SANWatch) support, including multi-pathing functions
  1. Easy management and monitoring of your subsystems anywhere, locally or remotely
  2. Recognize and manage redundant paths; support path failover and load-balancing
Multiple monitoring methods Real-time problem detection and notification to achieve continuous operation
Hardware Configurations
  1. Host Ports:
    1. Eight (8) 8Gb/s FC ports
    2. Four (4) 1Gb/s iSCSI ports
  2. Cache Memory: 8GB
  3. Drive connectivity: 6Gb/s
  4. Supported Drives:
    1. 73 or 146GB STEC ZeusIOPS SSD
    2. 147, 300, 450 or 600GB - 3.5" 15,000 RPM SAS drives
    3. 1 or 2TB -  3.5" 7,200 RPM SATA drives
  5. Maximum Number of Drives (per system): 16
  6. Maximum Number of Drives (via JBOD): 112
  7. Expansion Enclosure: ESVA J60-230
  8. Maximum Number of Drives (via scale-out*): 1344
  9. Form Factor: 3U
* Optional
Data Services
  1. Enterprise Scalable Virtualized Architecture
    1. Linear scaling of performance and capacity
    2. Storage Pooling
    3. Thin-provisioning
    4. Automatic Data Migration
    5. Prioritized Volume Accessibility
    6. Distributed Load Balance
  2. Data Protection
    1. Local Replication*
      1. Snapshot
      2. Volume Copy/Volume Mirror
      3. Quick Recovery
    2. Remote Replication*
      1. Synchronous and Asynchronous
      2. Data Compression
      3. Near Continuous Data Protection (N-CDP)
* Optional
Green
  1. 80 PLUS-certified power supplies delivering more than 80% energy efficiency
  2. Intelligent multi-level drive spin-down
Availability and Reliability
  1. Redundant, hot-swappable hardware modules
  2. CacheSafe technology
  3. Multi-pathing support (EonPath)
  4. Device mapper support
Notification Email, Fax, LAN broadcast, SNMP traps, SMS, MSN
Management
  1. SANWatch management suite
  2. Terminal via RS-232C
OS Support
  1. Windows Server 2003
  2. Windows Server 2008 (including Hyper-V)
  3. RedHat Enterprise Linux
  4. SUSE Linux Enterprise
  5. Sun Solaris
  6. IBM AIX*
  7. HP-UX*
  8. VMware
* Multipathing supported by Veritas

Service and Support

(Service may vary by regions)
  1. All ESVA systems are shipped with 3-year Standard Service.
  2. Standard Service:
    1. Hardware warranty; replacement part dispatch on the next business day
    2. Software update; 24x7 phone, web and email support
  3. Advanced Service*Standard service + Onsite diagnostics on the next business day
  4. Premium Service*: Standard service + Onsite diagnostics in 4 hours
* Optional
Power
  1. Power supplies: Two 530W DC
  2. AC voltage: 100VAC @ 10A to 240VAC @ 5A with PFC (auto-switching)
  3. Frequency: 47-63 Hz

Environmental

  1. Temperature: 0 to 40°C operating (35°C if BBU is applied) / -40 to 60°C non-operating
  2. Altitude: Sea level to 3660m (12,000ft) operating / sea level to 12,192m (40,000ft) non-operating
  3. Relative humidity: 5 to 95% non-condensing, operating and non-operating
Dimensions (without chassis ears / protrusions) 445mm (width) x 130mm (height) x 514mm (depth)
Weight (without HDDs) 19.66kg (43.69lbs)

Spare Parts

Battery backup unit 9373CCBM Cache backup module, Li-lon, Flash, for ESVA family, ESDS family and ES G6 subsystems, BBU ID
Optical FC cable 9270CFCCab02 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meters
Serial port Y-cable 9373AYCAB Serial port Y-cable for dual-controller subsystems, 2 audio jacks -to- 1 DB-9; maintenance-free during controller failover/failback
83SF28RF1661C RAID controller module for ESVA F60/F70-2830, SAS Exp. 4G DDR-II RAM
Power supply unit 9373CPSU Power supply unit for ESVA family, ESDS family and ES G6 2UR/12-bay and 3U/16-bay subsystems, 530W capacity
Small Form Pluggable Optical Transceiver 9370CSFP8G Avago Fibre Channel 8.5 / 4.25 / 2.125 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode
Slide rail assembly 9373CSlider36 Slide rail assembly, for ESVA family, ESDS family and ES G6 subsystems, 24"~36" rack depth

Accessories

9373CBBU Battery backup unit, Li-Ion, for ESVA family, ESDS family and ES G6 series subsystems, BBU ID
  9373CFBM Flash backup module, for  ESVA family, ESDS family and EonStor G6 subsystems
Optical FC cable 9270CFCCab01 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter
Optical FC cable 9270CFCCab03 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meters
9270CMSASCAB1 SAS external cable, MiniSAS 4X(SFF-8088) to MiniSAS 4X(SFF-8088), 50 Centimeters.
9270CMSASCAB2 SAS external cable, MiniSAS 4X(SFF-8088) to MiniSAS 4X(SFF-8088), 120 Centimeters.
9270CMSASCAB6 SAS external cable, SFF-8088 to SFF-8088, 170 Centimeters
  SOFT-DRSEV ESVA Local Replication License (Snapshot and Volume Copy/Mirror)
  SOFT-REM ESVA Remote Replication License 
  SOFT-SCOU ESVA Scale-Out License 
Drive Tray T41530HS2641 ESVA 300GB SAS 15K RPM HDD with drive tray
Drive Tray T41545HS2641 ESVA 450GB SAS 15K RPM HDD with drive tray
Drive Tray T41560HS2641 ESVA 600GB SAS 15K RPM HDD with drive tray
Drive Tray T472A0HA2321 ESVA 1TB SATA 7.2K RPM HDD with drive tray,  SAS-6G  MUX for Fx0-2830/Ex0-2x30/J60-230
Drive Tray T472A1HA2321 ESVA 2TB SATA 7.2K RPM HDD with drive tray,  SAS-6G  MUX for Fx0-2830/Ex0-2x30/J60-230
  SERV-PRERA 3-year Premium Service for ESVA Storage
  SERV-ADVRA 3-year Advanced Service for ESVA Strorage
  SERVE2-STARA 4th & 5th Year Standard  Service for ESVA Storage
  SERVE2-PRERA 4th & 5th Year Premium Service for ESVA Storage
  SERVE2-ADVRA 4th & 5th Year Advanced  Service for ESVA Storage

Integrating Scale-out Architecture in Today's Virtualized Environments