Massively Scalable, Outstanding-performance for Data-intensive Applications
The Infortrend ESVA F60 is designed to support a powerful, reliable and flexible Fibre Channel (FC) SAN. With high-performance drives, it can satisfactorily handle demanding transactional workloads. By connecting with expansion enclosures, the total capacity can be scaled up to 112 drives. By consolidating up to 12 ESVA systems into a storage pool, the maximum capacity can be further expanded to 1344 drives. The as-needed scaling allows users to increase storage for top-tier applications in the most cost-effective manner.
- Overview
- Features
- Specifications
- Accessories
Optimize Returns on Investment
With storage virtualization technology, the capacity and computing power of multiple ESVA systems can be consolidated into a storage pool. For the most efficient utilization of pooled storage capacity and bandwidth, ESVA systems support thin-provisioning and an intelligent access prioritizing mechanism on the virtual architecture. With these advanced features, storage utilization can be optimized and applications can achieve their ideal service levels. ESVA delivers advanced technologies to make the most of your storage investment.
Simplify Storage Infrastructure
ESVA simplifies storage management by enabling a single point of administration. Scaling the storage pool is also a very easy task and can be done without disrupting service. Each ESVA system can be scaled for increased capacity by connecting it to expansion enclosures. If you want to increase capacity and performance at the same time, you can also scale out the virtualized foundation by adding additional ESVA systems. When a new system is added, the distributed load balancing technology will dynamically balance workloads among storage systems and increase processing power.
Maximize Application Productivity
In the competitive business world, downtime not only causes profit loss but can inflict damage on corporate reputations. The revolutionary architecture of the ESVA eliminates planned downtime for storage scaling. To support business continuity, it also comes with storage-based replication capabilities. Local replication offers snapshot images and full data copies in a single storage pool, while remote replication enables users to deploy full data copies across storage pools. You enjoy the highest data availability and minimized service downtime in the event of logical or physical errors.
Advanced Hardware Designs
All ESVA systems are based on High Availability (HA) modular design to achieve high fault-tolerant capability. For better cached data protection, the ESVA systems come with built-in CacheSafe technology. In the event of a power outage, the BBU will automatically supply power to write cached data into flash memory for permanent retention. Infortrend enriches the ESVA Series with energy efficient designs, contributing to environmental sustainability while cutting energy costs for companies.| Features | Benefits |
|---|---|
| Storage virtualization | Eliminate physical boundaries of storage consolidation |
| Thin provisioning | Ensure the most efficient allocation of pooled capacity |
| Distributed load balancing | Make performance grow linearly by adding subsystems to the virtualized foundation |
| Prioritized volume accessibility | Ensure applications to achieve their ideal service levels |
Data protection:
|
Support the highest data availability and quick service restart after storage accidents |
| Eight or four 8Gb/s Fibre Channel host ports |
|
Green design:
|
|
| CacheSafe technology | Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage |
| Fault-tolerant hardware modules | Redundant controllers, PSUs, fans; high-availability hardware design, preventing "single-point-of-failure" |
| Maximum expansion of six JBODs via multi-lane SAS links, up to 112 HDDs in total | "Pay-as-you-grow" scalability; no waste on what you don’t need, and no worries in terms of forecasting what you will need in the future |
| Powerful management suite (SANWatch) support, including multi-pathing functions |
|
| Multiple monitoring methods | Real-time problem detection and notification to achieve continuous operation |
| Hardware Configurations |
* Optional |
|---|---|
| Data Services |
* Optional |
| Green |
* For ESVA F60-2830 only |
| Availability and Reliability |
|
| Notification | Email, Fax, LAN broadcast, SNMP traps, SMS, MSN |
| Management |
|
| OS Support |
* Multipathing supported by Veritas |
Service and Support (Service may vary by regions) |
* Optional |
| Power |
|
Environmental |
|
| Dimensions (without chassis ears / protrusions) | 445mm (width) x 130mm (height) x 514mm (depth) |
| Weight (with HDDs) | 19.66kg (43.69lbs) |
Spare Parts : F60-1830
| 9270CFCCab02 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meters | |
|---|---|---|
| 9373CCBM | Cache backup module, Li-lon, Flash, for ESVA family and ES ASIC 667 series subsystems, BBU ID | |
| 83SF18RF162C | RAID controller module for ESVA F60-1830, SAS Exp. 4G DDR-II RAM | |
| 9373CPSU | Power supply unit for ESVA family and ES ASIC667 2UR/12-bay and 3U/16-bay subsystems, 530W capacity | |
| 9373AYCAB | Serial port Y-cable for dual-controller subsystems, 2 DB-9 to 1 DB-9; maintenance-free during controller failover/failback | |
| 9370CSFP8G | Avago Fibre Channel 8.5 / 4.25 / 2.125 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode | |
| 9373CSlider36 | Slide rail assembly, for ESVA family and all ES ASIC667 subsystems, 24"~36" rack depth |
Spare Parts : F60-2830
| 9373CCBM | Cache backup module, Li-lon, Flash, for ESVA family, ESDS family and ES G6 subsystems, BBU ID | |
|---|---|---|
| 9270CFCCab02 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meters | |
| 9373AYCAB | Serial port Y-cable for dual-controller subsystems, 2 audio jacks -to- 1 DB-9; maintenance-free during controller failover/failback | |
| 83SF28RF161MC | RAID controller module for ESVA F60/F70-2830, SAS Exp. 4G DDR-II RAM | |
| 9373CPSU | Power supply unit for ESVA family, ESDS family and ES G6 2UR/12-bay and 3U/16-bay subsystems, 530W capacity | |
| 9370CSFP8G | Avago Fibre Channel 8.5 / 4.25 / 2.125 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode | |
| 9373CSlider36 | Slide rail assembly, for ESVA family, ESDS family and ES G6 subsystems, 24"~36" rack depth |
Accessories : F60-1830
| 9270CFCCab01 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter | |
|---|---|---|
| 9270CFCCab03 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meters | |
| 9270CMSASCAB1 | SAS external cable, MiniSAS 4X(SFF-8088) to MiniSAS 4X(SFF-8088), 50 Centimeters. | |
| 9270CMSASCAB2 | SAS external cable, MiniSAS 4X(SFF-8088) to MiniSAS 4X(SFF-8088), 120 Centimeters. | |
| 9270CMSASCAB6 | SAS external cable, SFF-8088 to SFF-8088, 170 Centimeters | |
| SOFT-DRSEV | ESVA Local Replication License (Snapshot and Volume Copy/Mirror) | |
| SOFT-REM | ESVA Remote Replication License | |
| SOFT-SCOU | ESVA Scale-Out License | |
| T41530HS2641 | ESVA 300GB SAS 15K RPM HDD with drive tray | |
| T41545HS2641 | ESVA 450GB SAS 15K RPM HDD with drive tray | |
| T41560HS2641 | ESVA 600GB SAS 15K RPM HDD with drive tray | |
| T472A0HA2321 | ESVA 1TB SATA 7.2K RPM HDD with drive tray, SAS-3G MUX for Fx0-1830/Ex0-1130/Jx0-130 | |
| T472A1HA2321 | ESVA 2TB SATA 7.2K RPM HDD with drive tray, SAS-3G MUX for Fx0-1830/Ex0-1130/Jx0-130 | |
| SERV-PRERA | 3-year Premium Service for ESVA Storage | |
| SERV-ADVRA | 3-year Advanced Service for ESVA Strorage | |
| SERVE2-STARA | 4th & 5th Year Standard Service for ESVA Storage | |
| SERVE2-PRERA | 4th & 5th Year Premium Service for ESVA Storage | |
| SERVE2-ADVRA | 4th & 5th Year Advanced Service for ESVA Storage |
Accessories : F60-2830
| 9373CBBU | Battery backup unit, Li-Ion, for ESVA family, ESDS family and ES G6 series subsystems, BBU ID | |
|---|---|---|
| 9373CFBM | Flash backup module, for ESVA family, ESDS family and EonStor G6 subsystems | |
| 9270CFCCab01 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1 Meter | |
| 9270CFCCab03 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meters | |
| 9270CMSASCAB1 | SAS external cable, MiniSAS 4X(SFF-8088) to MiniSAS 4X(SFF-8088), 50 Centimeters. | |
| 9270CMSASCAB2 | SAS external cable, MiniSAS 4X(SFF-8088) to MiniSAS 4X(SFF-8088), 120 Centimeters. | |
| 9270CMSASCAB6 | SAS external cable, SFF-8088 to SFF-8088, 170 Centimeters | |
| SOFT-DRSEV | ESVA Local Replication License (Snapshot and Volume Copy/Mirror) | |
| SOFT-REM | ESVA Remote Replication License | |
| SOFT-SCOU | ESVA Scale-Out License | |
| T41530HS2641 | ESVA 300GB SAS 15K RPM HDD with drive tray | |
| T41545HS2641 | ESVA 450GB SAS 15K RPM HDD with drive tray | |
| T41560HS2641 | ESVA 600GB SAS 15K RPM HDD with drive tray | |
| T472A0HA2321 | ESVA 1TB SATA 7.2K RPM HDD with drive tray, SAS-6G MUX for Fx0-2830/Ex0-2x30/J60-230 | |
| T472A1HA2321 | ESVA 2TB SATA 7.2K RPM HDD with drive tray, SAS-6G MUX for Fx0-2830/Ex0-2x30/J60-230 | |
| SERV-PRERA | 3-year Premium Service for ESVA Storage | |
| SERV-ADVRA | 3-year Advanced Service for ESVA Strorage | |
| SERVE2-STARA | 4th & 5th Year Standard Service for ESVA Storage | |
| SERVE2-PRERA | 4th & 5th Year Premium Service for ESVA Storage | |
| SERVE2-ADVRA | 4th & 5th Year Advanced Service for ESVA Storage |